High precision
Good linearity
Low temperature bleaching
Fast response time
Strong anti-interference ability
The sensor series open-loop Hall current sensor is insulated between primary and secondary and is used to control and measure DC, AC and pulse currents.
The magnetic flux generated by the primary current is gathered in the magnetic circuit and detected by the Hall element in the air gap. The output voltage of the Hall element is processed and the standard voltage signal is output at the output end of the sensor. The voltage signal accurately reflects the change of the primary current.
額定測
量電流
IPN(A)
|
額定測
量輸出
ISN(mA)
|
測量范圍
IPM(A)
|
負(fù)載電阻
RM(Ω)
|
型號
|
50 |
±50mA
|
0 - ±75
|
0-120
|
YNC-50I1
|
75 |
±50mA
|
0 - ±120
|
0-90
|
YNC-75I1
|
100 |
±50mA
|
0 - ±150
|
0-60
|
YNC-100I1
|
150 |
±75mA
|
0 - ±180
|
0-60
|
YNC-150I1
|
電源電壓 VC
|
±12 -- ±15V (±5%)
|
電流消耗 IC
|
≤10mA+輸出電流
|
一次側(cè)回路對二次側(cè)回路之間耐壓
|
2.5KV/50Hz/1min
|
準(zhǔn)確度 X
|
≤0.7%(+25℃)
|
線性度 εL
|
≤0.2%(+25℃)
|
零點(diǎn)偏移電流 IO
|
≤±0.1mA(+25℃)
|
零點(diǎn)溫度漂移 IOT
|
≤±0.5mA(-40℃~+85℃)
|
帶寬(-3db) BW
|
DC...200KHZ
|
響應(yīng)時間 Tr
|
≤1us
|
跟隨精度 di/dt
|
>200A/us
|
工作溫度 TA
|
儲存溫度 TS
|
重量 M
|
-40℃~+85℃
|
-40℃~+120℃
|
20g
|